| Sign In | Join Free | My ecer.co.uk |
|
Model NO. : E-110 SERIES
Clamping Insert : Nylon PA
Working Temperature : -40~100
Advantages : Fast Delivery
Size : M10-M100
Model Number : M10-M100
Key Words : Brass Cable Gland
Function : Cable Protection
Hot Searching : Atex Cable Gland
Samples : US$ 5/Piece 1 Piece(Min.Order) | Request Samp
Feature : Seal Part Hold Cable Firmly
MOQ : 100PCS
Work Temperature : 40~+100
Cable Gland : Waterproof
Thread Length : Standard & Customization
Other Size : Customization
Transport Package : Standard Export Carton
Specification : Metric / PG / G / NPT
Trademark : Golden Electric
Origin : China
HS Code : 33039649
Supply Ability : 5000/Month
Certification : ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001, IATF16949
Surface Treatment : Electroplating
Color : Metallic Color
IP Rating : IP68
Material : Brass Nickel Plated
Type : Straight Head
Customization : Available | Customized Request
Place of Origin : China
Brand Name : Golden Electric /OEM
MOQ : 1
Packaging Details : Carton/Pallet
Delivery Time : Peak Season Lead Time: more than 12 months Off Season Lead Time: within 15 workdays
Payment Terms : LC, T/T, PayPal, Western Union
Cap nut: Brass with nickel Plated
Clamping Insert: PA66 ( Flammability UL 94V-2)
Gland Body: Brass with nickel plated
Certificate: CE, IP68, ISO9001, TUV
Protection Class : IP68-10 BAR
Operating Temperature: -40 DEG to +100 DEG, (short time to 120 DEG); -20 DEG to 80 DEG, (short time to 100 DEG)
Function: Metal Cable Gland is cable supporting products, connector cable can be locked, the other end of the device can access the device through the box body, also can choose thread access according to the entry and outlet of the internal thread electrical equipment.
Product parameters:
| EMC Cable Gland - G,NPT thread | |||||||
| Product Code | Thread AG | Cable range(mm) | Thread O.D.(mm) | Mounting Hole Diameter (mm) | Thread length GL(mm) | Spanner Size (mm) | Std, Pkg (pcs) |
| JX-E.G1/4A-EMC | G1/4'' | 3-5.3 | 13.157 | 13.2-13.4 | 8 | 17/17 | 10 |
| JX-E.G1/4B-EMC | 4.5-7.8 | 13.157 | 13.2-13.4 | 8 | 17/17 | 10 | |
| JX-E.G3/8A-EMC | G3/8'' | 4-7 | 16.662 | 16.7-16.9 | 9 | 22/22 | 10 |
| JX-E.G3/8B-EMC | 6-10 | 16.662 | 16.7-16.9 | 9 | 22/22 | 10 | |
| JX-E.G1/2A-EMC | G1/2'' | 7-11 | 20.955 | 21-21.2 | 9.5 | 26/26 | 10 |
| JX-E.G1/2B-EMC | 9-14 | 20.955 | 21-21.2 | 9.5 | 26/26 | 10 | |
| JX-E.G3/4A-EMC | G3/4'' | 12-16 | 26.411 | 26.5-26.8 | 12 | 32/32 | 10 |
| JX-E.G3/4B-EMC | 14-18 | 26.411 | 26.5-26.8 | 12 | 32/32 | 10 | |
| JX-E.G1A-EMC | G1'' | 16-22 | 33.249 | 33.3-33.6 | 12.5 | 41/41 | 10 |
| JX-E.G1B-EMC | 18-25 | 33.249 | 33.3-33.6 | 12.5 | 41/41 | 10 | |
| JX-E.G11/4A-EMC | G1 1/4'' | 21-25 | 41.91 | 42-42.3 | 15 | 50/50 | 5 |
| JX-E.G11/4B-EMC | 24-30 | 41.91 | 42-42.3 | 15 | 50/50 | 5 | |
| JX-E.G11/2A-EMC | G1 1/2'' | 26-32 | 47.803 | 48-48.4 | 15 | 60/60 | 2 |
| JX-E.G11/2B-EMC | 31-41 | 47.803 | 48-48.4 | 15 | 60/60 | 2 | |
| JX-E.G2A-EMC | G2'' | 40-46 | 59.614 | 60-60.4 | 15 | 73/73 | 2 |
| JX-E.G2B-EMC | 44-51 | 59.614 | 60-60.4 | 15 | 73/73 | 2 | |
| JX-E.G21/2A-EMC | G2 1/2'' | 50-56 | 75.184 | 75.2-75.6 | 18 | 85/88 | 1 |
| JX-E.G21/2B-EMC | 56-66 | 75.184 | 75.2-75.6 | 18 | 85/88 | 1 | |
| JX-E.NPT3/8A-EMC | NPT3/8'' | 4-7 | 17.055 | 17.1-17.3 | 13 | 22/22 | 10 |
| JX-E.NPT3/8B-EMC | 6-10 | 17.055 | 17.1-17.3 | 13 | 22/22 | 10 | |
| JX-E.NPT1/2A-EMC | NPT1/2'' | 7-11 | 21.223 | 21-21.2 | 13 | 26/26 | 10 |
| JX-E.NPT1/2B-EMC | 9-14 | 21.223 | 21-21.2 | 13 | 26/26 | 10 | |
| JX-E.NPT3/4A-EMC | NPT3/4'' | 12-16 | 26.568 | 26.5-26.8 | 14 | 32/32 | 10 |
| JX-E.NPT3/4B-EMC | 14-18 | 26.568 | 26.5-26.8 | 14 | 32/32 | 10 | |
| JX-E.NPT1A-EMC | NPT1'' | 16-22 | 33.227 | 33.3-33.6 | 15 | 41/41 | 10 |
| JX-E.NPT1B-EMC | 18-25 | 33.227 | 33.3-33.6 | 15 | 41/41 | 10 | |
| JX-E.NPT11/4A-EMC | NPT1 1/4'' | 21-25 | 41.984 | 42-42.3 | 15 | 50/50 | 5 |
| JX-E.NPT11/4B-EMC | 24-30 | 41.984 | 42-42.3 | 15 | 50/50 | 5 | |
| EMC Cable Gland E Series- PG thread | |||||||
| Product Code | Thread AG | Cable range(mm) | Thread O.D.(mm) | Mounting Hole Diameter (mm) | Thread length GL(mm) | Spanner Size (mm) | Std, Pkg (pcs) |
| JX-E.PG7A-EMC | PG7 | 3-5.3 | 12.5 | 12.5-12.8 | 8 | 17/17 | 10 |
| JX-E.PG7B-EMC | 4.5-7.8 | 12.5 | 12.5-12.8 | 8 | 17/17 | 10 | |
| JX-E.PG9A-EMC | PG9 | 3-5.8 | 15.2 | 15.2-15.5 | 8 | 18/17 | 10 |
| JX-E.PG9B-EMC | 4.5-7.8 | 15.2 | 15.2-15.5 | 8 | 18/17 | 10 | |
| JX-E.PG11A-EMC | PG11 | 4-7 | 18.6 | 18.6-18.9 | 9 | 22/22 | 10 |
| JX-E.PG11B-EMC | 6-10 | 18.6 | 18.6-18.9 | 9 | 22/22 | 10 | |
| JX-E.PG13.5A-EMC | PG13.5 | 5-8.8 | 20.4 | 20.4-20.7 | 9.5 | 24/24 | 10 |
| JX-E.PG13.5B-EMC | 7-12 | 20.4 | 20.4-20.7 | 9.5 | 24/24 | 10 | |
| JX-E.PG16A-EMC | PG16 | 7-11 | 22.5 | 22.5-22.8 | 9.5 | 26/26 | 10 |
| JX-E.PG16B-EMC | 9-14 | 22.5 | 22.5-22.8 | 9.5 | 26/26 | 10 | |
| JX-E.PG21A-EMC | PG21 | 12-16 | 28.3 | 28.3-28.7 | 12 | 32/32 | 10 |
| JX-E.PG21B-EMC | 14-18 | 28.3 | 28.3-28.7 | 12 | 32/32 | 10 | |
| JX-E.PG29A-EMC | PG29 | 16-22 | 37 | 37-37.4 | 12.5 | 41/41 | 10 |
| JX-E.PG29B-EMC | 18-25 | 37 | 37-37.4 | 12.5 | 41/41 | 10 | |
| JX-E.PG36A-EMC | PG36 | 21-25 | 47 | 47-47.4 | 15 | 50/50 | 5 |
| JX-E.PG36B-EMC | 24-30 | 47 | 47-47.4 | 15 | 50/50 | 5 | |
| Brass EMC Cable Gland E Series- Metric thread | |||||||
| Product Code | Thread AG | Cable range(mm) | Thread O.D.(mm) | Mounting Hole Diameter (mm) | Thread length GL(mm) | Spanner Size (mm) | Std, Pkg (pcs) |
| JX-E.M12A-EMC | M12*1.5 | 3-5.3 | 12 | 12-12.3 | 8 | 17/17 | 5 |
| JX-E.M12B-EMC | 4.5-7.8 | 12 | 12-12.3 | 8 | 17/17 | 10 | |
| JX-E.M16A-EMC | M16*1.5 | 4-7 | 16 | 16-16.3 | 9 | 22/22 | 10 |
| JX-E.M16B-EMC | 6-10 | 16 | 16-16.3 | 9 | 22/22 | 10 | |
| JX-E.M20A-EMC | M20*1.5 | 5-8.8 | 20 | 20-20.3 | 9.5 | 24/24 | 10 |
| JX-E.M20B-EMC | 7-12 | 20 | 20-20.3 | 9.5 | 24/24 | 10 | |
| JX-E.M20C-EMC | 9-14 | 20 | 20-20.3 | 9.5 | 26/26 | 10 | |
| JX-E.M25A-EMC | M25*1.5 | 12-16 | 25 | 25-25.4 | 12 | 32/32 | 10 |
| JX-E.M25B-EMC | 14-18 | 25 | 25-25.4 | 12 | 32/32 | 10 | |
| JX-E.M32A-EMC | M32*1.5 | 16-22 | 32 | 32-32.4 | 12.5 | 41/41 | 10 |
| JX-E.M32B-EMC | 18-25 | 32 | 32-32.4 | 12.5 | 41/41 | 10 | |
| JX-E.M40A-EMC | M40*1.5 | 21-25 | 40 | 40-40.4 | 15 | 50/50 | 10 |
| JX-E.M40B-EMC | 24-30 | 40 | 40-40.4 | 15 | 50/50 | 5 | |
| JX-E.M50A-EMC | M50*1.5 | 26-32 | 50 | 50-50.4 | 15 | 60/60 | 2 |
| JX-E.M50B-EMC | 31-41 | 50 | 50-50.4 | 15 | 60/60 | 2 | |
| JX-E.M63A-EMC | M63*1.5 | 40-46 | 63 | 63-63.4 | 15 | 73/73 | 2 |
| JX-E.M63B-EMC | 44-51 | 63 | 63-63.4 | 15 | 73/73 | 2 | |
| JX-E.M75A-EMC | M75*1.5 | 50-56 | 75 | 75-75.6 | 15 | 85/88 | 1 |
| JX-E.M75B-EMC | 56-66 | 75 | 75-75.6 | 15 | 85/88 | 1 | |
| JX-E.M90A-EMC | M90*1.5 | 58-68 | 90 | 90-91 | 20 | 102/106 | 1 |
| JX-E.M90B-EMC | 66-77 | 90 | 90-91 | 20 | 102/106 | 1 | |
| JX-E.M100A-EMC | M100*1.5 | 58-68 | 100 | 100-101 | 25 | 116/120 | 1 |
| X-E.M100B-EMC | 66-77 | 100 | 100-101 | 25 | 116/120 | 1 | |
Cable glands are mechanical cable entry devices. They are used throughout a number of industries in conjunction with cable and wiring used in elelctrical instrumentation and automation systems.
Cable gland may be used on all types of electrical power, control, instrumentation, data and telecommunications cables. They are used as a sealing and termination device to ensure that the charachteristcs of the enclosure which the cable enters can be maintained adequately.